Phone: (540) 961-3576
Fax: (540) 953-3010 e-mail: mkt@vatell.com
AMP-11
AMP-11
(for use with ThermogageTM)
specification sheet
also available in PDF file
Advantages:
- Compact Size (1
1/4" x 1 1/2" x 4")
- Light Weight (5.6
oz)
- Self-contained
Battery
- 72 Hours Operating
Time between Battery Charges
- High Common Mode
Noise Rejection
Specifications:
Input Impedance
600 Ohms
Output Impedance
1 ohm
Maximum Voltage
Out ± 2.5
Principle
of Operation:
This amplifier can be used with many Thermogage™
Heat Flux Transducers to increase the transducer sensitivity. A frequent
application is when fast response phenomena are to be measured. The
fastest Thermogage™ Heat Flux Transducer has a response time of 0.003 seconds.
However, such a transducer has an extremely low sensitivity of 5,000 to
10,000 W/cm2 for 10mV linear output. Measuring heat fluxes in lower
ranges therefore requires use of the amplifier. For example, if we
use such a transducer with a sensitivity of 5,000 W/cm2 for 10mV output
and connect it to the amplifier at 100 gain, the resulting sensitivity
is 5W/cm2 per millivolt output.
Going to the other extreme, the most sensitive Thermogage™ Heat Flux Transducer has a sensitivity of 5W/cm2 for 10 millivolt output. This transducer can be used with the amplifier at 1,000 gain to produce a sensitivity of 0.0005W/cm2 per millivolt and is sensitive enough to measure moonlight and other feeble heat sources such as the heat from the human body.
Operating
Instructions:
1. Gain step switch and gain trim screw
are factory-set and should not be moved or calibration will be lost. Both
are covered
with silicone rubber
to prevent tampering.
2. The zero balance screw is to be used
only if necessary to line up the recorder zero with the amplifier
zero.
3. The unit battery is activated when
the nine-pin connector plug is connected. In order to conserve battery
life, disconnect
connector when not
in service, or, activate and use the off-on switch. The off-on switch
is only usable if the jumper
between pins K and F is removed.
The battery provided should run approximately 72 hours.
4. The battery bottom is exposed.
It is held in place by the electrical connection snaps. Pull straight
out to remove battery.
The battery is very
firmly held in place and may require pliers to facilitate removal.